Meritsun Battery Problems & Warranty Issues: My Real 3-Year Experience With LFP200-48 Batteries

Meritsun Battery Problems & Warranty Issues: My Real Long-Term Experience With Two LFP200-48 Batteries

Are you considering buying a Meritsun battery, Meritsun Powerwall, Meritsun LFP200-48, Meritsun 10kWh battery or another Meritsun LiFePO4 solar battery?

Before spending a large amount of money, I strongly recommend reading this complete report.

This is not a review written after using a battery for a few days. It is based on several years of ownership, repeated technical problems, direct discussions with Meritsun support, detailed monitoring of the internal PACE BMS, thousands of recorded measurements and research into problems reported publicly by other Meritsun battery owners.

I purchased two Meritsun LFP200-48 batteries in 2022. Each battery was sold as approximately 48V, 200Ah and 10kWh, giving me roughly 20kWh of nominal storage capacity.

The total price for the two batteries was approximately PHP 340,000.

At that price, I expected a professional residential energy-storage product with serious long-term support.

Instead, I eventually found myself diagnosing individual cell voltages, BMS calibration, SOC errors, communication protocols, balancing problems and possible degraded cells.

This article describes my own documented experience and also references publicly available reports from other Meritsun owners. A complaint from one customer does not prove that every Meritsun battery is defective. Likewise, forum reports do not by themselves prove a systematic manufacturing defect. I provide the original links so readers can examine the discussions themselves.


My Meritsun LFP200-48 Setup

  • Two Meritsun LFP200-48 batteries
  • Approximately 10kWh nominal capacity per battery
  • 200Ah nominal capacity per battery
  • 48V class LiFePO4 system
  • Two batteries connected in parallel
  • Deye 8kW hybrid inverter
  • PACE AM-series BMS
  • BMS firmware identified as P15S100A-12640-2.03

The batteries were purchased together and operated as one residential solar-energy-storage system.

The problems did not suddenly appear in 2026 after years of perfect operation.

My support history with Meritsun goes back to early 2024.


January 2024: One Meritsun Battery Was Already Discharging Faster

In January 2024, approximately one year and a few months after purchase, I contacted Meritsun because one of the two batteries appeared to discharge significantly faster than the other.

At the time, I told Meritsun that the batteries had completed only around 300 charge and discharge cycles.

Meritsun asked for videos, pictures and historical data so they could analyse the problem.

I initially managed to improve the situation by resetting the BMS.

However, that did not permanently solve the underlying behaviour.


February 2024: Meritsun Acknowledged SOC May Not Be Fully Accurate

During further discussions in February 2024, I asked about recommended depth of discharge and inverter configuration.

Meritsun told me that 80% DOD was their recommendation.

They also told me:

“sometimes, the soc will be not 100% accurate”

This is important because SOC accuracy continued to become a recurring issue during the lifetime of the system.

Meritsun advised checking battery voltage against SOC and later recommended that I operate the batteries using voltage mode.

They recommended approximately:

  • 54V charging voltage
  • 48V cut-off voltage
  • Additional inverter thresholds around 48V, 49V and 50V

I explicitly asked whether the remaining configuration was correct.

The Meritsun representative confirmed that it was.

At that point, I thanked them because I genuinely believed the problem could be solved through configuration.

Unfortunately, the problems continued.


February 2024: Two Identical Batteries Behaving Differently

I contacted Meritsun again because the two batteries connected in parallel were not charging and discharging in the same way.

Meritsun told me that two batteries connected in parallel should normally remain at the same voltage level.

They suggested checking the connections, disconnecting and reconnecting the batteries, then charging both batteries fully.

This became part of a recurring troubleshooting cycle:

  • check connections
  • reset BMS
  • reconnect batteries
  • fully recharge
  • check SOC
  • check voltage
  • check inverter settings

These are reasonable diagnostic steps once.

They become much less reassuring when the problem continues returning on expensive commercial batteries.


April 2024: Meritsun Suspected a Signal-Wire Problem

In April 2024, another abnormal condition appeared.

Meritsun support told me:

“it looks like the signal wire is loose”

They said the battery case would need to be opened and checked.

I contacted the person who originally sold the batteries and asked what would happen if defective cells needed replacement.

At that time, Meritsun replied that they did not believe the issue was related to the cells.

They believed it was more likely related to the signal wire.

That becomes interesting when compared with the technical data collected later, because the BMS eventually showed severe and persistent differences between specific monitored cell groups.


March 2025: BMS Firmware and Historical Data

In March 2025, I contacted Meritsun again and asked if a newer BMS firmware was available.

Meritsun told me that the firmware for this battery generation dated from approximately May 2022.

They asked me to connect to the batteries using PC monitoring software and export the historical BMS records.

I did exactly what they requested.

I sent the exported data to Meritsun for analysis.

After reviewing the records, Meritsun told me that one set of data appeared normal while the other showed cells at a low voltage and that the battery needed to be recharged so the cells could balance.

Therefore, cell imbalance was already appearing in the BMS records in 2025.


Meritsun, Deye, CAN, RS485 and Voltage Mode

Communication with the Deye inverter also became part of the problem.

I questioned why the batteries could not simply use a reliable Pylontech-compatible CAN protocol with the Deye inverter.

I tested different communication approaches and ordered dedicated RS485 cables.

I was trying to obtain reliable individual battery information including:

  • voltage
  • SOC
  • temperature
  • charge status
  • discharge status

Meritsun again recommended switching to battery voltage mode and allowing the batteries to charge and discharge for several cycles to improve the relationship between SOC and voltage.

This illustrates one of the central frustrations of my ownership experience.

I did not buy loose LiFePO4 cells and a DIY BMS kit.

I bought finished commercial residential batteries.

Yet I gradually found myself doing work normally associated with a battery technician or system integrator.


2026: I Built Direct PACE BMS Monitoring

Eventually I stopped relying only on the SOC displayed by the inverter.

I built a monitoring system that collected information directly from the internal PACE BMS of each battery.

The monitoring system recorded:

  • all 15 monitored cell-group voltages
  • pack voltage
  • current
  • SOC
  • SOH
  • remaining capacity
  • learned full capacity
  • cycle count
  • warnings
  • protection states

The information was stored automatically in a database at regular intervals.

My monitoring period included more than 16,000 five-minute records and 8,491 valid intervals containing complete positional cell data for both batteries.

Missing communication values and zero-value records were excluded from cell analysis.

This was therefore not based on one screenshot or one random reading.

It was persistent historical monitoring.


Meritsun Battery Pack 1: Cell 9 Repeatedly Became the Weakest

On the first Meritsun LFP200-48 battery, monitored Cell 9 was the lowest-voltage group in approximately 76% of all valid measurements.

Out of 8,491 valid measurement intervals, Cell 9 was the lowest in 6,451 intervals.

The lowest voltage recorded for Cell 9 was:

2.715V

At the same moment, the highest monitored cell group was approximately:

3.194V

This created a difference of approximately:

479mV

The recorded imbalance was not occasional.

  • 1,650 intervals had a difference of at least 80mV
  • 1,129 intervals had a difference of at least 120mV
  • 818 intervals had a difference of at least 200mV

An earlier historical event showed an absolute maximum difference of approximately:

726mV

During charging, another monitored group, Cell 13, was recorded at approximately:

3.814V

while Cell 9 remained significantly lower.


Pack 1 Capacity: 200Ah Design, Approximately 133Ah Learned Capacity

The BMS information for the first battery showed:

  • Design capacity: 200Ah
  • BMS learned full capacity: approximately 133.06Ah
  • Reported SOH: approximately 66.53%
  • Cycle count: approximately 955

There are two possible interpretations.

If the learned capacity accurately reflects usable battery capacity, the battery has lost a very substantial amount of capacity relative to its nominal specification.

If the value is inaccurate, then the BMS capacity calculation itself requires serious recalibration.

Neither explanation is particularly reassuring for an expensive home-storage battery.


Meritsun Battery Pack 2: Cell 12 Repeatedly Became the Weakest

The second battery showed a different persistent weak group.

Cell 12 was the lowest-voltage group in approximately 83% of all valid intervals.

It was the lowest in 7,040 of 8,491 measurements.

The lowest recorded voltage was:

2.701V

At the same moment, the highest group was approximately:

3.280V

This created a difference of approximately:

575mV

The second battery produced even more frequent large imbalances:

  • 3,995 intervals at or above 80mV
  • 2,679 intervals at or above 120mV
  • 1,937 intervals at or above 200mV

The BMS eventually entered:

Lower Cell Voltage Protection

That is no longer a cosmetic SOC difference.

The battery-management system was protecting the pack because a monitored cell group reached its lower-voltage threshold prematurely.


Pack 2 Reported 106.86% SOH

The BMS for Pack 2 reported:

  • Design capacity: 200Ah
  • Learned full capacity: approximately 213.71Ah
  • Reported SOH: 106.86%
  • Cycle count: approximately 812

A nominal 200Ah battery showing 213.71Ah learned capacity and more than 106% state of health clearly deserves investigation.

Meritsun later agreed that this appeared consistent with BMS capacity and SOH miscalibration.


Meritsun's Own Root Cause Analysis

This is probably the most important part of the entire story.

I sent Meritsun the detailed technical report.

I did not simply complain that “my batteries are bad”.

I provided them with long-term BMS data.

Meritsun replied with a technical Root Cause Analysis.

For Pack 1, they described:

“Severe cell imbalance / capacity degradation in specific cells”

They specifically referred to Cell 9 dropping to approximately 2.715V under discharge and Cell 13 reaching approximately 3.814V during charging.

Meritsun stated that the passive balancing of the PACE BMS, typically around 30 to 50mA according to their response, could not compensate for an imbalance this large.

For Pack 2, Meritsun stated:

“This indicates a weak/degraded cell”

They referred directly to Cell 12 dropping to approximately 2.701V while other groups remained near 3.28V.

Regarding the 106.86% SOH and 213.71Ah learned capacity, Meritsun described this as consistent with PACE BMS coulomb-counter drift following micro-cycling or severe imbalance.

In other words, the manufacturer's own technical response identified:

  • severe cell imbalance
  • capacity degradation
  • a weak or degraded cell
  • insufficient passive balancing for the current deviation
  • BMS SOC/SOH calibration drift

I Asked Meritsun for the Exact Repair Procedure

I told Meritsun I was prepared to follow an official procedure.

I requested:

  1. The exact PBMS Tool version.
  2. The exact firmware compatible with my BMS.
  3. The required RS232 or RS485 cable.
  4. The exact communication pinout.
  5. The complete SOC/SOH recalibration procedure.
  6. The correct balancing parameters.
  7. The exact manual top-balancing or active-equalization procedure.
  8. Confirmation of whether opening the batteries was required.
  9. Written confirmation that following their procedure would not affect the warranty.
  10. The official warranty/RMA process.
  11. Contact details for authorized technical support.

I do not believe a customer should randomly flash firmware, alter BMS parameters or dismantle a high-energy lithium battery without precise written instructions from the manufacturer.

And I certainly do not want to open or modify the batteries only to be told later that I invalidated the warranty.


The Original Retailer Is No Longer Available

The original retailer is no longer operating.

This makes manufacturer support even more important.

A serious long-term battery warranty is of limited practical value if the customer is left without an effective support channel once a reseller disappears.

That is exactly why prospective buyers should ask before purchasing:

  • Who handles the warranty if the retailer closes?
  • Is there an official local service centre?
  • Does Meritsun handle warranty claims directly?
  • Are replacement BMS units available?
  • Are replacement cells available?
  • Who performs repairs?
  • Who pays transport?

Meritsun Currently Advertises Long-Term Warranty Support

Meritsun's current residential battery marketing advertises a long warranty period and technical support.

Official Meritsun residential battery page:

https://www.meritsunbattery.com/en/residentialhome-a812.html

Current marketing does not automatically prove which exact warranty conditions applied to a battery purchased in 2022.

That distinction is important.

However, customers buying expensive storage products marketed around long service life and long warranty periods are entitled to ask what that support actually looks like when a technical failure develops.


Other Meritsun Battery Owners Have Reported Problems

My experience is not the only negative Meritsun battery experience publicly available online.

The following are reports published by other owners.

These individual reports do not prove that every Meritsun battery has the same defect, but they are highly relevant for anyone researching Meritsun battery problems, Meritsun battery reviews, Meritsun BMS problems, Meritsun warranty issues or Meritsun customer support.


1. PowerForum: “MERITSUN BMS FAILED”

A Meritsun owner reported a major BMS-related failure involving a 50V 100Ah LiFePO4 battery.

The user measured approximately 48V internally while only around 12V was available at the external battery terminals.

The battery's LCD display was also reportedly dead.

Original discussion:

PowerForum - MERITSUN BMS FAILED


2. Another Meritsun Battery Goes Offline in the Same PowerForum Thread

A second owner later added another report involving a Meritsun 48V 100Ah battery.

The battery reportedly went completely offline and stopped communicating with the inverter.

Original discussion:

PowerForum - Meritsun BMS / communication failure discussion


3. DIY Solar Forum: Meritsun/Meritech Batteries Cutting Out During Discharge

A DIY Solar Forum owner discussed Meritsun/Meritech batteries that sometimes cut out during discharge before reaching the expected normal discharge point.

Original discussion:

DIY Solar Forum - Any experience with Meritsun/Meritech here?

This is especially relevant when compared with my own battery data, where weak monitored groups eventually reached low-voltage protection before the remainder of the pack was equivalently discharged.


4. DIY Solar Forum: Meritsun CANBUS Charging Limit Problem

Another public thread is titled:

“Sol-Ark 12K + Meritsun - CANBUS seeing wrong charging limits.”

The discussion concerns charging limits being incorrectly communicated through CANBUS when multiple Meritsun batteries were connected.

Original discussion:

DIY Solar Forum - Sol-Ark + Meritsun CANBUS problem


5. Victron Community: Two 10kWh Meritsun Batteries Would Not Discharge Below 39%

A particularly interesting case involves two parallel Meritsun 10kWh batteries.

The owner reported that the batteries charged normally but would not discharge below approximately 39% SOC despite the system minimum being configured at 15%.

The owner also described discrepancies between battery SOC and the surrounding PACE/Victron system.

Original discussion:

Victron Community Archive - Meritsun 10kWh battery SOC problem


6. Victron Community: Meritsun SOC Not in Sync With SmartShunt

Another owner reported a large discrepancy between the remaining capacity shown by the Meritsun battery and the value calculated by a Victron SmartShunt.

Original discussion:

Victron Community Archive - Meritsun SOC not in sync


7. Victron ESS: Meritsun Communication and Charging Problems

Another discussion concerns Meritsun Powerwall batteries being detected as Pylontech batteries in a Victron ESS installation.

The user experienced charging and communication issues and eventually reported that the batteries could charge when used in a more basic configuration without normal BMS communication.

Original discussion:

Victron Community Archive - Meritsun batteries in ESS


8. Facebook: Meritsun 200Ah Battery Not Charging or Discharging

A public Facebook discussion describes a 200Ah Meritsun battery that reportedly would neither charge nor discharge even though the displayed cell voltages appeared relatively close together.

Original post:

Facebook - Meritsun 200Ah battery not charging or discharging

Facebook group access may depend on login or membership.


9. Facebook: Deye Inverter Unable to Detect Meritsun Battery

Another discussion concerns a Deye inverter that reportedly could not detect a Meritsun lithium battery correctly.

Original discussion:

Facebook - Deye / Meritsun battery communication issue

Another similar Deye/Meritsun discussion:

Facebook - Deye not detecting Meritsun batteries


10. Facebook: Owner Seeking Help Replacing Meritsun Powerwall Cells

Another owner publicly asked for assistance troubleshooting and replacing cells in a Meritsun 48V Powerwall that reportedly would no longer hold charge correctly.

Original discussion:

Facebook - Meritsun Powerwall cell repair discussion


11. YouTube: “Unbalanced Cell MERITSUN Battery Repair”

A publicly available repair video is specifically titled:

“Unbalanced Cell MERITSUN Battery Repair”

Video:

YouTube - Unbalanced Cell MERITSUN Battery Repair

A repair video obviously does not prove that an entire product line is defective.

It does, however, provide another public example involving a Meritsun battery and cell imbalance.


What These Reports Have in Common

The publicly reported issues include:

  • BMS failure
  • battery going offline
  • loss of communication
  • incorrect SOC
  • CAN communication problems
  • premature discharge cut-off
  • charging problems
  • batteries refusing to discharge as expected
  • cell imbalance
  • owners seeking BMS repairs
  • owners seeking replacement cells

Again, different users may have different causes and configurations.

I am not claiming they all have one identical manufacturing defect.

But for a prospective buyer researching Meritsun batteries, these are exactly the kinds of real-world reports worth reading before spending thousands.


The Biggest Problem: The Customer Becomes the Battery Technician

If I had built a DIY battery myself, I would accept responsibility for troubleshooting it.

If I purchased individual cells, busbars and a BMS from an online marketplace, I would know exactly what I was getting into.

But this was a finished residential energy-storage product.

Over time, however, I have had to investigate:

  • BMS resets
  • SOC calibration
  • SOH calibration
  • CAN communication
  • RS485 communication
  • Deye settings
  • voltage mode
  • special communication cables
  • firmware
  • cell balancing
  • individual cell-group voltages
  • historical BMS logs
  • database storage
  • weak cells
  • low-cell protection

At some point, it no longer feels like ownership of a commercial battery.

It feels like an engineering project.


My Opinion About Meritsun Support

I want this article to remain factually accurate.

Meritsun has replied to multiple messages over the years.

It would be inaccurate to say that nobody ever responded.

They provided configuration advice.

They asked for technical data.

They analysed my BMS information.

My criticism is more specific:

Technical replies are not the same as an actual resolution.

Once the manufacturer's own analysis identifies severe cell imbalance, capacity degradation and a weak/degraded cell, I expect the process to move toward repair, replacement, authorized service or a clear warranty decision.

I do not expect another endless diagnostic loop.


If You Want No Local Support and a Battery Problem on Your Hands, Think Carefully Before Buying

If you are considering spending a very large amount of money on a Meritsun battery system, investigate the local support situation first.

Because if you eventually have a battery containing many kilowatt-hours of lithium storage with a weak cell or BMS problem, you cannot simply put it in a parcel and send it across the world like a phone charger.

You need a real support structure.

You need someone who can answer:

  • Who diagnoses the battery?
  • Who opens it?
  • Who replaces cells?
  • Who replaces the BMS?
  • Who balances the pack?
  • Who provides firmware?
  • Who handles shipping?
  • Who accepts responsibility under warranty?

If you want to spend a lot of money and then potentially find yourself alone with a very large battery that nobody locally wants to repair, then my experience shows exactly why you should investigate Meritsun's after-sales structure before buying.


Would I Buy Meritsun Again?

No.

Based on my own experience with these two batteries, I would not purchase the same system again.

That is my personal conclusion.

I paid a premium price because I expected reliable long-term energy storage.

I did not expect:

  • unequal battery behaviour relatively early
  • repeated SOC issues
  • communication troubleshooting
  • voltage-mode workarounds
  • cell imbalance
  • cells approaching low-voltage protection
  • hundreds of millivolts of cell difference
  • one BMS reporting approximately 66.5% SOH
  • another BMS reporting more than 106% SOH
  • years of diagnostic work

Most importantly, once Meritsun itself described the problem as severe cell imbalance, capacity degradation and a weak/degraded cell, I expected a concrete path toward repair or warranty resolution.


What I Expect From Meritsun

My request is simple and reasonable.

I want a technically appropriate solution under the warranty terms that apply to these batteries.

That could include:

  • authorized professional diagnosis
  • BMS recalibration
  • proper balancing
  • replacement of defective cells
  • replacement of a defective BMS
  • replacement of a battery if necessary

I am willing to provide logs, BMS records and technical information.

I am not willing to blindly modify high-energy lithium batteries without written manufacturer instructions.


This Meritsun Battery Review Will Be Updated

I will update this article when the situation changes.

If Meritsun resolves the problem correctly, repairs the batteries or honours the applicable warranty, I will document that.

If no effective solution is provided, I will also document that.

Potential buyers deserve to see the complete outcome.


Meritsun Battery Problems: Useful Public Sources


Frequently Asked Questions About Meritsun Batteries

Are Meritsun batteries reliable?

Some owners may operate Meritsun batteries without significant problems, but my own experience with two LFP200-48 batteries has involved persistent cell imbalance, BMS/SOC problems and extensive troubleshooting. Other users have also published reports involving BMS failures, communication problems and abnormal battery behaviour.

Do Meritsun batteries have BMS problems?

Public reports exist involving Meritsun BMS failure and loss of communication. My own PACE BMS data also showed inconsistent SOH and learned-capacity values requiring investigation.

Can Meritsun batteries have cell imbalance?

My two batteries both developed persistent imbalance involving repeatedly weak monitored cell groups. Meritsun itself described my data as showing severe cell imbalance and capacity degradation.

Does Meritsun work with Deye inverters?

Meritsun batteries can be used with Deye equipment, but my own system required significant troubleshooting involving CAN, RS485, SOC behaviour and voltage-mode operation.

Does Meritsun provide a long battery warranty?

Meritsun currently advertises long-term warranty and technical support on its residential battery website. Owners should verify the exact written warranty applicable to their specific battery model, serial number and purchase date.

Would I recommend the Meritsun LFP200-48?

Based on my personal experience with two units, no. I would only consider this type of product if there were clearly documented local warranty support, spare parts and an authorized repair network.


Conclusion: Research Meritsun Battery Problems Before Buying

Battery brochures are full of attractive numbers:

  • 10kWh
  • 200Ah
  • LiFePO4
  • Grade A cells
  • thousands of cycles
  • intelligent BMS
  • long warranty

The real test begins when something goes wrong.

My Meritsun battery experience has included early unequal battery behaviour, SOC discrepancies, communication issues, repeated troubleshooting, significant cell imbalance, low-voltage protection and BMS capacity values that required recalibration.

Most importantly, Meritsun's own technical response eventually described severe cell imbalance, capacity degradation and a weak/degraded cell.

That is why this page exists.

If you are researching:

Meritsun battery, Meritsun battery problems, Meritsun battery review, Meritsun warranty, Meritsun battery support, Meritsun LFP200-48, Meritsun Powerwall, Meritsun BMS problem, Meritsun battery cell imbalance, Meritsun 10kWh battery, Meritsun LiFePO4 battery or Meritsun battery Philippines, read independent owner experiences before making your decision.

Do not only research how a battery performs when it is new. Research what happens when it fails.



FRANÇAIS : Problèmes de batteries Meritsun, BMS, cellules déséquilibrées, SAV et garantie - Mon expérience réelle avec deux LFP200-48

Vous envisagez d'acheter une batterie Meritsun, une Meritsun Powerwall, une Meritsun LFP200-48, une batterie solaire Meritsun de 10kWh ou une batterie LiFePO4 Meritsun ?

Avant de dépenser une somme importante, je vous conseille fortement de lire cette expérience complète.

Il ne s'agit pas d'un avis écrit après quelques jours d'utilisation.

Mon expérience repose sur plusieurs années d'utilisation, des échanges répétés avec le support Meritsun, une surveillance directe des BMS PACE internes, des milliers de mesures enregistrées et des recherches sur les problèmes rencontrés publiquement par d'autres propriétaires de batteries Meritsun.

J'ai acheté en 2022 deux batteries Meritsun LFP200-48.

Chaque batterie était annoncée autour de 48V, 200Ah et 10kWh, soit environ 20kWh de capacité nominale totale.

Le prix total payé était d'environ 340 000 PHP.

À ce prix, je pensais acheter un système professionnel de stockage résidentiel avec une réelle fiabilité et un support technique digne du prix du produit.

Je ne pensais certainement pas finir par analyser moi-même les tensions de cellules, le SOC, le SOH, la calibration du BMS, les protocoles CAN et RS485 et les problèmes d'équilibrage.

Cette page décrit mon expérience personnelle documentée et cite également des témoignages publics d'autres propriétaires Meritsun.

Un témoignage individuel ne prouve évidemment pas que toutes les batteries Meritsun sont défectueuses.

Les liens originaux sont fournis afin que chacun puisse vérifier les discussions.


Configuration de mon installation Meritsun

  • Deux batteries Meritsun LFP200-48
  • Environ 10kWh chacune
  • 200Ah nominal par batterie
  • Système LiFePO4 48V
  • Deux batteries en parallèle
  • Onduleur hybride Deye 8kW
  • BMS PACE
  • Firmware identifié P15S100A-12640-2.03

Les deux batteries ont été achetées ensemble et utilisées sur la même installation.

Les problèmes ne sont pas apparus brutalement en 2026 après plusieurs années parfaites.

Mon historique de discussions avec Meritsun remonte déjà à 2024.


Janvier 2024 : une batterie se décharge déjà plus rapidement

En janvier 2024, environ un an et quelques mois après l'achat, j'ai contacté Meritsun parce qu'une des deux batteries se déchargeait plus rapidement que l'autre.

À cette époque, j'avais indiqué environ 300 cycles de charge et de décharge.

Meritsun m'a demandé des vidéos, des photos et des données.

Un reset du BMS avait temporairement amélioré la situation.

Mais le comportement anormal est revenu.


Février 2024 : Meritsun reconnaît que le SOC peut être imprécis

Lors d'une discussion sur la profondeur de décharge et les réglages du Deye, Meritsun m'a indiqué recommander environ 80% de DOD.

Le support m'a également répondu :

“sometimes, the soc will be not 100% accurate”

Autrement dit, Meritsun reconnaissait déjà que le SOC pouvait ne pas être parfaitement précis.

Ils m'ont ensuite recommandé d'utiliser le système en mode tension.

Ils m'ont indiqué environ :

  • 54V pour la charge
  • 48V pour la coupure
  • des seuils supplémentaires autour de 48V, 49V et 50V

Je leur ai demandé si le reste de la configuration était correct.

Meritsun m'a confirmé que oui.

À ce moment-là, je pensais encore qu'un simple réglage allait résoudre définitivement le problème.


Deux batteries identiques qui ne se comportent pas pareil

Quelques jours plus tard, j'ai de nouveau signalé une différence de charge entre les deux batteries.

Meritsun m'a indiqué que deux batteries en parallèle devraient normalement rester au même niveau de tension.

Ils m'ont conseillé de contrôler les connexions, de débrancher et rebrancher les batteries puis de les charger complètement.

Petit à petit, la gestion du système est devenue une succession de :

  • reset BMS
  • contrôle de branchement
  • recharge complète
  • comparaison SOC/tension
  • modification de paramètres

Ce sont des manipulations normales pour diagnostiquer un problème une fois.

Sur des batteries résidentielles très coûteuses, cela devient beaucoup moins acceptable lorsque le problème revient régulièrement.


Avril 2024 : Meritsun soupçonne un câble de signal

En avril 2024, un nouveau problème apparaît.

Meritsun me répond :

“it looks like the signal wire is loose”

Ils m'indiquent alors qu'il faudrait ouvrir la batterie pour contrôler le câblage.

Je leur demande ce qui se passe si des cellules sont défectueuses.

À ce moment-là, Meritsun pense encore que le problème n'est probablement pas lié aux cellules mais au câblage de mesure.

Ce détail est aujourd'hui intéressant puisque les mesures réalisées plus tard montrent des écarts très importants et persistants entre certains groupes surveillés.


Mars 2025 : historique BMS et cellules basses

En mars 2025, je demande s'il existe un nouveau firmware BMS.

Meritsun m'indique que le firmware de cette génération remonte approximativement à mai 2022.

Ils me demandent ensuite de connecter les batteries au logiciel PC et d'exporter les historiques.

Je leur transmets les fichiers.

Après analyse, Meritsun me répond que certaines données montrent des cellules à basse tension et que la batterie doit être rechargée pour équilibrer les cellules.

Le déséquilibre des cellules était donc déjà visible dans les données BMS en 2025.


CAN, RS485, Deye et mode tension

La communication avec l'onduleur Deye est également devenue une source de complications.

J'ai essayé différentes configurations CAN et RS485.

J'ai commandé des câbles spécifiques.

Je cherchais simplement à obtenir des informations fiables pour chaque batterie :

  • tension
  • SOC
  • température
  • état de charge
  • état de décharge

Meritsun m'a de nouveau recommandé de travailler en mode tension et de faire plusieurs cycles afin de recalibrer le rapport entre tension et SOC.

À ce stade, il faut rappeler une chose simple.

Je n'avais pas acheté des cellules nues avec un BMS DIY.

J'avais acheté des batteries commerciales complètes.


2026 : surveillance directe des BMS PACE

À force de ne pas comprendre précisément ce qui se passait, j'ai mis en place mon propre système de monitoring.

Les données étaient lues directement depuis les BMS PACE internes.

J'enregistrais :

  • les 15 tensions surveillées par batterie
  • la tension totale
  • le courant
  • le SOC
  • le SOH
  • la capacité restante
  • la capacité complète apprise par le BMS
  • le nombre de cycles
  • les alarmes
  • les protections

Les données étaient sauvegardées automatiquement dans une base de données.

J'ai obtenu plus de 16 000 enregistrements de cinq minutes et 8 491 intervalles complets utilisables pour comparer les cellules des deux batteries.

Les valeurs manquantes ou les erreurs de communication ont été supprimées de l'analyse.

Nous ne parlons donc pas d'une photo prise au mauvais moment.

Nous parlons de semaines de données.


Batterie 1 : la Cell 9 est faible environ 76% du temps

Sur la première batterie, la Cell 9 est la tension la plus basse dans 6 451 mesures sur 8 491.

Soit environ :

76% du temps.

Sa tension minimale enregistrée est :

2,715V

Alors que la cellule la plus élevée se trouvait encore à environ :

3,194V

L'écart atteignait :

479mV

Les écarts importants se répètent :

  • 1 650 mesures avec au moins 80mV d'écart
  • 1 129 mesures avec au moins 120mV
  • 818 mesures avec au moins 200mV

Un maximum historique d'environ :

726mV

a également été enregistré.

Pendant une phase de charge, la Cell 13 est même montée à environ :

3,814V

pendant que la Cell 9 restait nettement plus basse.


Batterie 1 : 200Ah nominaux mais environ 133Ah appris par le BMS

Le BMS indiquait :

  • capacité de conception : 200Ah
  • capacité complète apprise : environ 133,06Ah
  • SOH : environ 66,53%
  • nombre de cycles : environ 955

Si cette capacité apprise correspond réellement à la capacité utilisable, la perte est considérable.

Si elle est fausse, alors le BMS est mal calibré.

Dans les deux cas, il y a un problème à résoudre.


Batterie 2 : Cell 12 faible environ 83% du temps

Sur la seconde batterie, la Cell 12 était la plus faible sur 7 040 des 8 491 mesures.

Soit environ :

83% du temps.

La tension minimale enregistrée est :

2,701V

Alors qu'une autre cellule était encore autour de :

3,280V

Soit un écart de :

575mV.

Les déséquilibres importants ont été encore plus fréquents :

  • 3 995 mesures à au moins 80mV
  • 2 679 mesures à au moins 120mV
  • 1 937 mesures à au moins 200mV

Le BMS est finalement passé en :

Lower Cell Voltage Protection.

Autrement dit, une cellule surveillée atteignait sa tension minimale alors que les autres étaient encore beaucoup plus hautes.


Un SOH de 106,86% sur une batterie de 200Ah

Le second BMS indiquait :

  • capacité nominale : 200Ah
  • capacité apprise : environ 213,71Ah
  • SOH : environ 106,86%
  • nombre de cycles : environ 812

Une batterie de 200Ah affichant plus de 213Ah et plus de 106% de SOH mérite évidemment une explication.

Meritsun a ensuite reconnu que cette valeur était compatible avec une dérive du compteur de coulombs et un problème de calibration du BMS.


Le diagnostic technique de Meritsun

C'est probablement la partie la plus importante de ce dossier.

J'ai envoyé à Meritsun l'ensemble de mon analyse.

Ils m'ont répondu avec leur propre Root Cause Analysis.

Pour la batterie 1, Meritsun écrit :

“Severe cell imbalance / capacity degradation in specific cells”

Ils citent précisément la Cell 9 qui descend à environ 2,715V et la Cell 13 qui monte à environ 3,814V.

Ils indiquent également que l'équilibrage passif du BMS PACE ne peut pas suivre un écart aussi important.

Pour la batterie 2, Meritsun écrit :

“This indicates a weak/degraded cell”

Ils parlent directement de la Cell 12 descendant à environ 2,701V pendant que les autres restent nettement plus hautes.

Pour le SOH de 106,86% et les 213,71Ah, ils parlent d'une dérive du compteur de coulombs du BMS.

Autrement dit, leur propre analyse technique évoque :

  • un déséquilibre sévère des cellules
  • une dégradation de capacité
  • une cellule faible ou dégradée
  • un équilibrage passif insuffisant pour corriger l'écart
  • une calibration SOC/SOH incorrecte

J'ai demandé une vraie procédure de réparation

J'ai demandé à Meritsun :

  1. la version exacte de PBMS Tool
  2. le firmware exact correspondant à mon BMS
  3. le type de câble
  4. le brochage RS232/RS485
  5. la procédure exacte de recalibration SOC/SOH
  6. les paramètres d'équilibrage
  7. la procédure de top balancing ou d'équilibrage actif
  8. si cette opération nécessite l'ouverture de la batterie
  9. si Meritsun m'autorise officiellement à l'ouvrir
  10. si cela affecte la garantie
  11. la procédure officielle RMA/garantie
  12. un contact technique agréé

Je refuse de modifier au hasard les paramètres internes d'une batterie lithium de plusieurs kilowattheures.

Et je refuse également de l'ouvrir sans autorisation écrite pour ensuite entendre que la garantie est annulée.


Le revendeur original a fermé

Le revendeur chez qui j'ai acheté les batteries n'existe plus.

Cela montre exactement pourquoi le support du fabricant est essentiel.

Une garantie longue durée ne sert pas à grand-chose si tout dépend d'un revendeur local qui peut disparaître deux ans plus tard.

Avant d'acheter, demandez donc :

  • Que se passe-t-il si le revendeur ferme ?
  • Meritsun prend-il directement le dossier ?
  • Existe-t-il un centre de réparation officiel ?
  • Les cellules de remplacement sont-elles disponibles ?
  • Les BMS de remplacement sont-ils disponibles ?
  • Qui paie le transport ?

D'autres utilisateurs signalent également des problèmes Meritsun

Mon cas n'est pas le seul problème Meritsun disponible publiquement.

Encore une fois, ces témoignages ne prouvent pas que toutes les batteries Meritsun présentent le même défaut.

Mais ils doivent être lus par toute personne recherchant :

batterie Meritsun, problème batterie Meritsun, avis Meritsun, SAV Meritsun, garantie Meritsun, problème BMS Meritsun, Meritsun LFP200-48 ou batterie solaire Meritsun.


1. PowerForum : BMS Meritsun en panne

Un propriétaire d'une Meritsun 50V 100Ah rapporte que la batterie ne délivrait plus qu'environ 12V aux bornes alors que la tension interne du pack restait proche de 48V.

L'écran LCD était également hors service.

PowerForum - MERITSUN BMS FAILED


2. Une autre batterie Meritsun devient totalement offline

Dans la même discussion, un autre propriétaire indique plus tard qu'une Meritsun 48V 100Ah est devenue complètement offline et ne communiquait plus avec l'onduleur.

PowerForum - problème BMS et communication Meritsun


3. DIY Solar Forum : batteries qui coupent pendant la décharge

Un utilisateur Meritsun/Meritech explique rencontrer des coupures pendant la décharge avant d'atteindre le niveau de décharge normalement attendu.

DIY Solar Forum - expérience Meritsun/Meritech


4. DIY Solar Forum : problème de limites CANBUS avec Meritsun

Une autre discussion concerne un Sol-Ark 12K et des batteries Meritsun dont les limites de charge semblent incorrectement transmises via CANBUS.

DIY Solar Forum - Meritsun CANBUS


5. Victron : deux Meritsun 10kWh refusent de descendre sous 39%

Un propriétaire de deux batteries Meritsun 10kWh en parallèle rapporte qu'elles ne descendent jamais sous environ 39% de SOC alors que le minimum du système est réglé à 15%.

Il constate également des différences entre le SOC des batteries et les données du système PACE/Victron.

Victron Community - Meritsun 10kWh SOC


6. Victron : SOC Meritsun différent du SmartShunt

Un autre utilisateur signale une différence importante entre le SOC affiché par sa batterie Meritsun et celui calculé par un Victron SmartShunt.

Victron Community - Meritsun SOC


7. Victron ESS : problèmes de communication et de charge

Un autre utilisateur de Powerwall Meritsun rencontre des difficultés de communication dans son installation Victron ESS.

Victron Community - Meritsun batteries in ESS


8. Facebook : Meritsun 200Ah qui ne charge et ne décharge plus

Une publication Facebook décrit une batterie Meritsun 200Ah ne chargeant et ne déchargeant plus normalement.

Facebook - problème Meritsun 200Ah


9. Facebook : Deye ne détecte pas correctement une batterie Meritsun

Une autre discussion concerne un onduleur Deye incapable de détecter correctement une batterie Meritsun en mode lithium.

Facebook - Deye et Meritsun

Autre discussion similaire :

Facebook - Deye ne détecte pas les batteries Meritsun


10. Facebook : propriétaire cherchant à remplacer des cellules Meritsun

Un propriétaire recherche de l'aide pour diagnostiquer et remplacer des cellules dans une Powerwall Meritsun 48V ne tenant plus correctement la charge.

Facebook - réparation cellules Meritsun


11. YouTube : “Unbalanced Cell MERITSUN Battery Repair”

Il existe également une vidéo publique intitulée :

“Unbalanced Cell MERITSUN Battery Repair”

YouTube - réparation batterie Meritsun cellules déséquilibrées


Quels problèmes retrouve-t-on dans les témoignages ?

  • BMS en panne
  • batterie offline
  • perte de communication
  • SOC incohérent
  • problèmes CANBUS
  • coupures prématurées en décharge
  • problèmes de charge
  • batterie ne déchargeant pas toute sa capacité
  • déséquilibre des cellules
  • recherche de BMS de remplacement
  • recherche de cellules de remplacement

Les causes peuvent évidemment différer d'une installation à l'autre.

Mais lorsqu'on envisage de dépenser une grosse somme dans une batterie solaire, ce sont précisément ces retours qu'il faut lire avant l'achat.


Le vrai problème : le client finit technicien batterie

Si j'avais fabriqué moi-même une batterie DIY, j'accepterais complètement de devoir la diagnostiquer.

Mais j'ai acheté un produit commercial fini.

Et pourtant j'ai dû apprendre à gérer :

  • les resets BMS
  • le SOC
  • le SOH
  • la calibration
  • le CAN
  • le RS485
  • les réglages Deye
  • le mode tension
  • les câbles spécifiques
  • le firmware
  • l'équilibrage
  • les tensions individuelles
  • les bases de données de monitoring
  • les protections basse tension

À un moment, cela ne ressemble plus à l'utilisation normale d'une batterie résidentielle.


Mon avis sur le support Meritsun

Je veux être précis.

Meritsun m'a répondu plusieurs fois.

Ils m'ont donné des réglages.

Ils m'ont demandé des données.

Ils ont analysé mon rapport.

Je ne dirai donc pas qu'ils n'ont jamais répondu.

Mon problème est différent :

répondre n'est pas résoudre.

Quand le propre diagnostic du fabricant parle de déséquilibre sévère, de perte de capacité et de cellule faible/dégradée, j'attends ensuite une vraie procédure de réparation, une prise en charge ou une décision de garantie.

Pas une nouvelle boucle interminable de tests.


Si vous voulez vous retrouver avec une batterie très chère sur les bras, vérifiez le SAV avant d'acheter

Une batterie solaire de 10 ou 20kWh n'est pas un téléphone qu'on renvoie facilement par la poste.

Quand elle tombe en panne, il faut une vraie infrastructure de support.

Avant d'acheter Meritsun, demandez clairement :

  • Qui diagnostique la batterie ?
  • Qui ouvre la batterie ?
  • Qui remplace les cellules ?
  • Qui remplace le BMS ?
  • Qui effectue l'équilibrage ?
  • Qui fournit le firmware ?
  • Qui paie le transport ?
  • Qui applique réellement la garantie ?

Si vous voulez éviter de vous retrouver seul avec plusieurs dizaines de kilowattheures de batteries très coûteuses et aucun technicien local capable ou autorisé à intervenir, posez ces questions avant de payer.


Est-ce que je rachèterais Meritsun ?

Non.

Avec mon expérience actuelle, je ne rachèterais pas le même système.

C'est mon avis personnel basé sur mes deux batteries.

J'ai payé cher parce que je voulais un stockage énergétique fiable sur le long terme.

Je ne m'attendais pas à :

  • des différences entre les deux batteries dès les premières années
  • des SOC incohérents
  • des problèmes de communication
  • des contournements en mode tension
  • des cellules fortement déséquilibrées
  • des protections basse tension
  • des écarts de plusieurs centaines de millivolts
  • une batterie à environ 66,5% de SOH affiché
  • une autre batterie à plus de 106% de SOH affiché
  • des années de diagnostic

Et quand Meritsun lui-même parle finalement de :

“Severe cell imbalance / capacity degradation”

et de :

“weak/degraded cell”

j'attends une vraie solution.


Ce que j'attends maintenant de Meritsun

Je demande simplement une solution technique adaptée aux conditions de garantie applicables à mes batteries.

Par exemple :

  • diagnostic professionnel agréé
  • recalibration du BMS
  • équilibrage correct
  • remplacement des cellules défectueuses
  • remplacement du BMS si nécessaire
  • remplacement de la batterie si elle ne peut pas être réparée correctement

Je suis prêt à fournir toutes les données techniques.

Je refuse simplement de bricoler au hasard une batterie lithium de forte capacité sans instructions écrites du fabricant.


Cet avis Meritsun sera mis à jour

Je mettrai cette page à jour lorsque la situation évoluera.

Si Meritsun règle correctement le problème, répare les batteries ou applique la garantie applicable, je l'écrirai.

Si aucune solution concrète n'est apportée, je l'indiquerai également.

Les futurs acheteurs doivent pouvoir voir l'histoire complète.


Sources publiques sur les problèmes de batteries Meritsun


FAQ : avis et problèmes batteries Meritsun

Les batteries Meritsun sont-elles fiables ?

Certaines installations peuvent fonctionner correctement, mais mon expérience avec deux LFP200-48 a impliqué des problèmes persistants de cellules, de SOC, de BMS et de communication. D'autres propriétaires ont également publié des problèmes similaires ou différents sur plusieurs forums spécialisés.

Les batteries Meritsun ont-elles des problèmes de BMS ?

Il existe des témoignages publics parlant de BMS Meritsun en panne ou de perte de communication. Mes propres BMS PACE ont également affiché des valeurs de capacité et de SOH nécessitant une recalibration.

Les batteries Meritsun peuvent-elles avoir des cellules déséquilibrées ?

Dans mon cas, oui. Les deux batteries présentent des groupes de cellules systématiquement plus faibles, avec des écarts atteignant plusieurs centaines de millivolts. Meritsun lui-même a décrit les données comme montrant un déséquilibre sévère.

Meritsun fonctionne-t-il avec Deye ?

Oui, les batteries peuvent fonctionner avec des onduleurs Deye, mais mon expérience a nécessité beaucoup de diagnostic concernant CAN, RS485, SOC et mode tension.

La garantie Meritsun est-elle de 10 ans ?

Meritsun affiche actuellement une garantie longue durée sur ses produits résidentiels. Il faut cependant demander les conditions écrites correspondant exactement au modèle, au numéro de série et à l'année d'achat.

Est-ce que je recommande Meritsun LFP200-48 ?

Avec mon expérience actuelle sur deux batteries, non. Je ne rachèterais ce type de produit que si un véritable réseau local de réparation, de pièces détachées et de garantie était clairement documenté avant l'achat.


Conclusion : cherchez les problèmes Meritsun avant d'acheter

Les brochures commerciales parlent toujours de :

  • 10kWh
  • 200Ah
  • LiFePO4
  • cellules Grade A
  • milliers de cycles
  • BMS intelligent
  • garantie longue durée

Mais la vraie valeur d'un fabricant se voit lorsque la batterie rencontre un problème.

Mon expérience avec Meritsun comprend des différences entre batteries relativement tôt, des problèmes de SOC, des difficultés de communication, des cellules fortement déséquilibrées, une protection basse tension et des valeurs de capacité BMS incohérentes.

Le propre support de Meritsun a ensuite parlé de déséquilibre sévère, de dégradation de capacité et de cellule faible ou dégradée.

C'est la raison pour laquelle cette page existe.

Si vous recherchez :

batterie Meritsun, problème batterie Meritsun, avis Meritsun, garantie Meritsun, SAV Meritsun, Meritsun LFP200-48, problème BMS Meritsun, batterie solaire Meritsun, Meritsun Powerwall, Meritsun 10kWh ou Meritsun LiFePO4, prenez le temps de lire les expériences réelles des propriétaires avant d'acheter.

Ne cherchez pas uniquement comment une batterie fonctionne lorsqu'elle est neuve. Cherchez surtout ce qui se passe lorsqu'elle tombe en panne.

Commentaires